Home > Products > Gas Solenoid Valve > Dual Modular Solenoid valve

  • Dual Modular Solenoid valve

    Dual Modular Solenoid valve

    Description:

    //  The dual modular solenoid valve consist of two safety shutoff valves in one compact fitting:

    // Solenoid shutoff valves as per DIN EN161 Class A Group 2

    // Two A valves in one compact body

    // Two valve blocks

    // High flow rate

    // Max pressure 500mbar

    // Fast closing

    // Fast or slow opening, with fast initial gas allowance

    // Main volume adjustable

    // Flexible combination between flange and thread

    // Applicable to gases, such as natural gas, methane, LPG and so on

    // Blue signal light indicates working status

    // Compact and light weight


    Share
    INQUIRE NOW
Dual Modular Solenoid valve
Description and Application

Description:

//  The dual modular solenoid valve consist of two safety shutoff valves in one compact fitting:

// Solenoid shutoff valves as per DIN EN161 Class A Group 2

// Two A valves in one compact body

// Two valve blocks

// High flow rate

// Max pressure 500mbar

// Fast closing

// Fast or slow opening, with fast initial gas allowance

// Main volume adjustable

// Flexible combination between flange and thread

// Applicable to gases, such as natural gas, methane, LPG and so on

// Blue signal light indicates working status

// Compact and light weight


LCV-D:

Two solenoid valves, both are fast opening and fast closing with main volume restrictor at V2 to adjust flow rate.

LCV-DLE:

Two solenoid valves, V1 is fast opening and V2 is slow opening. Both opening time and main volume can be adjusted at V2. 

双-快开+慢开DN32.jpg


Technical Specification

Technical Data:

Structure

503

507

512

Flange connection with pipe threads as per ISO7/1

Rp3/8, Rp1/2

Rp1/2, Rp3/4, Rp1, Rp1 1/4

Rp1 1/4, Rp1 1/2, Rp2

Max working pressure: 500mbar (50Kpa)


Valve V1: Solenoid shut-off valve as per DIN EN161 Class A Group 2


Valve V2: Solenoid shut-off valve as per DIN EN161 Class A Group 2


Closing time:<1s


Opening time:

LCV-D<1s

LCV-DLE = about 15s at +20℃ without initial lift


Initial lift:Adjustable for LCV-DLE


Main Volume:Adjustable at V2 for both LCV-BD and LCV-BDLE


Material:

Valve Body: Brass, Steel, Aluminum Alloy 

Sealing: NBR for G260/1 gases


Temperature: -12℃ to +60℃


Installation position: Vertical or horizontal 


Filter: Built-in filter screen, proper filter should be installed;


Sensors or detectors connection: G1/8 as per DIN ISO 228 at the inlet end of V1, between V1 and V2, and at the outlet end of V2 


Voltage/Frequency: 50/60Hz,230V±15% (others can be customize)


Working time: 100% of all time


Protection: IP54


Electrical connection: As per DIN43650


Interference: Degree N


Overall Dimensions and item No.


Model

Pmax

Connection

Dimensions[mm]

Weight

[mbar]

Rp

A

B

C

D

E

F

G

[Kg]

LCV-D507

500

Rp3/4 DN20









LCV-D510

500

Rp1 DN25









LCV-D511

500

Rp1 1/4 DN32









LCV-D512

500

Rp1 1/4DN32

126

190

48.75

144

98.5

103

216


LCV-D515

500

Rp1 1/2DN40

126

190

48.75

144

98.5

103

216

4.1

LCV-D520

500

Rp2 DN50

126

190

48.75

144

98.5

103

216



LCV-DLE507

500

Rp3/4 DN20









LCV-DLE510

500

Rp1 DN25









LCV-DLE511

500

Rp1 1/4 DN32









LCV-DLE512

500

Rp1 1/4DN32

126

190

48.75

205

98.5

103

216


LCV-DLE515

500

Rp1 1/2 DN40

126

190

48.75

205

98.5

103

216


LCV-DLE520

500

Rp2 DN50

126

190

48.75

205

98.5

103

216



image.png

Online Services