Home > Products > Combustion controller > TM-681 Series

  • TM-681 Series Combustion Controller

    TM-681 Series Combustion Controller

    Related parameter:

    Rated voltage:AC220V~230V  50/60Hz(-15%~+10%)

    Environment temperature:Single equipment  installation:-20~+60°C

    More than two sets of equipment installation:-20~+45°C

    Environment humidity:lower than 90%RH (can’t be used in condensation environment)

    Shockproof performance:each side of x,y,z is shock-resistant for 0.5G and the frequency is 10-150Hz

    Insulation class: when the DC current is 500V, the resistance of the terminal to ground is higher than 50MΩ.

    Insulator strength: when the AC current is 1800V for 1 second or AC 1500V for 1 minute, the terminal-to-ground leakage is lower than10mA(except for flame detector terminals)

    Design life: 100,000 times normal operation(In the case of meeting all external conditions)

    Terminal load:5A

    Size:Width 126.5 x height 76 x thickness 86mm

    Weight: Net weight is about 500G


    Share
    INQUIRE NOW
TM-681 Series
Description and Application

TM 681 series flame controllers are designed for flame detection and control of industrial kilns or combustion systems. Various functions such as automatic ignition,  flame detection indication, flameout protection, fault alarm indication, dual-stage control combustion for various other gas fuels and liquid burners.Widely used in gas or oil burner of metallurgy, ceramics,glass, chemical, building materials, casting and other industries .

TM-681 series flame controller needs to be used with UV photosensitive tubprobes or ion flame probes.



Technical Specification

Related parameter:

Rated voltage:AC220V~230V  50/60Hz(-15%~+10%)

Environment temperature:Single equipment  installation:-20~+60°C

More than two sets of equipment installation:-20~+45°C

Environment humidity:lower than 90%RH (can’t be used in condensation environment)

Shockproof performance:each side of x,y,z is shock-resistant for 0.5G and the frequency is 10-150Hz

Insulation class: when the DC current is 500V, the resistance of the terminal to ground is higher than 50MΩ.

Insulator strength: when the AC current is 1800V for 1 second or AC 1500V for 1 minute, the terminal-to-ground leakage is lower than10mA(except for flame detector terminals)

Design life: 100,000 times normal operation(In the case of meeting all external conditions)

Terminal load:5A

Size:Width 126.5 x height 76 x thickness 86mm

Weight: Net weight is about 500G


Overall Dimensions and item No.


55.png


22.jpg


445.png

Online Services
Whatsapp Skype